Agent Not Communicating with the Enterprise Manager
If the Agent isn't communicating with the Enterprise Manager, the following questions should be addressed:
-
Is there a firewall blocking communication?
- If yes, ensure the Windows Firewall has an ‘inbound’ rule to open port 3136 and an ‘outbound’ rule to open port 3136.
- Alternatively, have an ‘inbound’ rule to ‘allow connection’ (General tab) for the Agent,
(default path is
…\Netwrix\Threat Prevention\SIWindowsAgent\SIWindowsAgent.exe) specified on the Program and Services tab along with selecting the This Program radio button.
-
Does the server where the Agent has been deployed have multiple network adapters (multi-homed)?
- If yes, then the Agent is likely trying to communicate with the Enterprise Manager through the wrong network. See the Bind To topic to resolve this issue.
contact Netwrix Support if these recommendations do not resolve the issue.
Bind To
For the Agent to communicate in a multiple network card environment, uncomment the ‘… bindTo …’ line in the SIWindowsAgent.exe.config file and set it to the IP address of the network adapter you want to use (on the Agent) or the name of the network adapter you want to use for communicating with the Enterprise Manager. The installer will attempt to configure this setting if it detects multiple NICs. If the chosen setting doesn’t work in your environment, set it manually.
The default location of the SIWindowsAgent.exe.config file is:
…\Netwrix\Netwrix Threat Prevention\SIWindowsAgent