Configure Fortinet FortiGate Devices

Netwrix Auditor relies on native logs for collecting audit data. Therefore, successful change and access auditing requires a certain configuration of native audit settings in the audited environment and on the Auditor console computer. Configuring your IT infrastructure may also include enabling certain built-in Windows services, etc. Proper audit configuration is required to ensure audit data integrity, otherwise your change reports may contain warnings, errors or incomplete audit data.

CAUTION: Folder associated with Netwrix Auditor must be excluded from antivirus scanning. See the Antivirus Exclusions for Netwrix Auditor knowledge base article for additional information.

You can configure your IT Infrastructure for monitoring in one of the following ways:

  • Automatically through a monitoring plan – This is a recommended method. If you select to automatically configure audit in the target environment, your current audit settings will be checked on each data collection and adjusted if necessary.

  • Manually – Native audit settings must be adjusted manually to ensure collecting comprehensive and reliable audit data. You can enable Auditor to continually enforce the relevant audit policies or configure them manually:

    • The target Fortinet Fortigate device must be configured via Command Line Interface (CLI) as described below.

To configure your Fortinet FortiGate devices, enable logging to multiple Syslog servers and configure FortiOS to send log messages to remote syslog servers in CEF format. Do one of the following:

  • To configure Fortinet FortiGate devices via Command Line Interface
  • To configure Fortinet FortiGate devices through the Fortigate Management Console

To configure Fortinet FortiGate devices via Command Line Interface

  1. Log in to the Command Line Interface (CLI).

  2. Enter the following commands:

    config log syslogd setting

    set format cef

    To enable CEF format in some previous FortiOS versions, enter the set csv disable command.

    set csv disable

    set facility <facility_name>

    set port 514

    set reliable disable

    set server <ip_address_of_Receiver>

    set status enable

    end

To configure Fortinet FortiGate devices through the Fortigate Management Console

  1. Open Fortigate Management Console and navigate to Log&Report ® Log Config ® Log Setting.

  2. Select the Syslog checkbox.

  3. Expand the Options section and complete the following fields:

    OptionDescription
    Name/IPEnter the address of your Netwrix Auditor Server.
    PortSet to "514".
    LevelSelect desired logging level.
    FacilityNetwrix recommends using default values.
    Data formatSelect CEF. To enable CEF format in some previous FortiOS versions, unselect the Enable CSV checkbox.
  4. Click Apply.

Fortinet FortiGate Devices

Review a full list of object types Netwrix Auditor can collect on Fortinet FortiGate devices.

Object typeActionsLogID
Authentication- Successful logon- 0100029002 - 0102043039 - 0102043008 - 0102043029 - 0101037138 / act=tunnel-up
- Failed logon- 0100029003 - 0101039426 - 0102043009 - 0102043010 - 0101037121 / XAUTH authentication failed
Configuration- Copied- 0100032211 - 0100032300
- Modified / Modify (Failed attempt)- 0100032102 - 0100032104 - 0100032400 - 0100044544 - 0100044545 - 0100044546 - 0100044547 - 0100032565 - 0100032566 - 0100032567 - 0100032571 - 0100032199 - 0100032202 - 0100032203 - 0100032234 - 0100032235 - 0108035012 - 0100044548
- Read / Read (Failed attempt)- 0100032226 - 0100032228 - 0100032229 - 0100032230
Logon- Successful logon- 0100032001
- Failed logon- 0100032002 - 0100032021
Rule- Activated- 0419016384 - 0419016385 - 0419016386 - 0421016399 - 0211008192 - 0211008194 - 0203008200 - 0212008448 - 0261008450 - 0212008452 - 0212008457 - 0213008704 - 0213008706 - 0263008720 - 0262008960 - 0262008962 - 0262008964 - 0262008966 - 0262008968 - 0262008970 - 0262008972 - 0262008974 - 0211009234 - 0211009236 - 0202009248 - 0954024576 - 0954024579 - 0720018432 - 0720018433 - 0720018434
Session- Logoff- 0100032003 - 0102043040
User- Add / Remove- 0100032129 - 0100032131 - 0100032132
- Modified / Modify (Failed attempt)- 0100032130