Skip to main content

Configure Security Event Log Maximum Size

Follow the steps to configure Event Log maximum size:

Step 1 – On your file server, create a new file system where the security log will be stored.

Step 2 – Mount this file system on a mount point, e.g., /events.

Step 3 – Make sure that it is accessible via the \<file_server_name>\C$\events UNC path.

Step 4 – On the computer where Auditor Server is installed, open Registry Editor: navigate to Start → Run and type "regedit".

Step 5 – Navigate to File → Connect Network Registry and specify the file server name.

Step 6 – Navigate to HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\EventLog\Security and set the File value to "C:\events\security.evt".

Step 7 – Set the MaxSize value to "4 000 000 000 (decimal)".